Smart Management
-
High Security
-
Multiple Communication
-
Metering Data Storage
ADVANTAGES:
1. CERTIFICATION
STS 2.O, DLMS/COSEM
2. APPLICATION
THREE PHASE FOUR WIRE
3. COMMUNICATION
PLC, RF, GSM/GPR
HL3000M offers multiple anti-tampering and advanced security features that ensures revenue protection for our customers. The site diagnostic capability continuously monitors the service, verifying that all phases are present and that the wiring configuration is correct. Adverse or abnormal conditions, such as phase outages and reverse energy events, are logged.
HL3000M offers high security with various useful security features. The meter stores all registration and configuration data to nonvolatile memory. All data is retained for the life of the meter. The data can be read out by local and remote communication. Recordable security features are provided.
1. CERTIFICATION
STS 2.O, DLMS/COSEM
2. APPLICATION
THREE PHASE FOUR WIRE
3. COMMUNICATION
PLC, RF, GSM/GPR
HL3000M offers multiple anti-tampering and advanced security features that ensures revenue protection for our customers. The site diagnostic capability continuously monitors the service, verifying that all phases are present and that the wiring configuration is correct. Adverse or abnormal conditions, such as phase outages and reverse energy events, are logged.
HL3000M offers high security with various useful security features. The meter stores all registration and configuration data to nonvolatile memory. All data is retained for the life of the meter. The data can be read out by local and remote communication. Recordable security features are provided.
-
Description Specification
Reference voltage (Un) 3X110-230V/190-400V Operation voltage 70% Un~120% Un Limit of Voltage 0% Un~120% Un Basic current (In) 5A Maximum current (Imax) 100A Short-circuit current 3,000A, <3ms, no damage or accuracy deviation after restoration Frequency 50/60Hz Frequency rage 47.5~52.5Hz Accuracy class Cl.1.0 for active energy, Cl.2 for reactive energy -
EMC Specification
Electrostatic discharge (ESD) Contact discharge: 8kV
Air discharge: 15kV, IEC 61000-4-2Fast transient burst 4 KV/100 KHZ, IEC 61000-4-4 Immunity to HF Fields 80MHz-2GHz@10V/m with load; 80MHz-2GHz@30V/m with no load Conducted disturbances by RF 150kHz - 80MHz 10V/m, IEC 61000-4-6 Radio Interference CISPR 22, IEC 61000-4-2,3,4,6 Surge Immunity 30KA/KV , 4/10S against lightening, IEC 61000-4-5 -
Consumption Specification
Voltage circuit <2W, 8VA @230V Current circuit <1VA @ Base current (Ib) -
Insulation Specification
Impulse voltage (1.2/50µS) >8KV coil to contact; >4KV contact to contact AC voltage (1MIN, 50HZ) 4KV coil to contact; 2KV contact to contact -
Environment Specification
Operating Temperature -25º C~75º C Storage Temperature -40º C~85º C Humidity average ≤95%, maximum ≤100%, non-condensing Altitude ≤3000m